Annnnndddd. I just laid all the perlens for the green house along it's length to mark them for the hoops and it just started raining.
π6π3
Making a saddle for welding pipes.... the magic angle is 32degrees. https://www.youtube.com/watch?v=L77I6b68uI0
YouTube
How to Cut Perfect Pipe Saddles with a Chop Saw
In this video I show you how I cope pipe using a dry cut chop saw. This method leave you with a really clean joint and is fairly quick to do. I use my SteelMax cold cut saw with a Diablo blade on it.
Hereβs a link for the SteelMax Chop saw
https://amzn.to/3MLW29Rβ¦
Hereβs a link for the SteelMax Chop saw
https://amzn.to/3MLW29Rβ¦
π7β€3
Forwarded from πrue πΈnarchy (FeelsGood)
The same busybody, petty bureaucrats who cry about global warming and legislate for a net zero carbon future will also take your kids into care if you choose to live off grid in the woods!
On Thursday, a judge in the town of LβAquila upheld prosecutorsβ claims that the children were suffering from βserious harmβ owing to their parentsβ back-to-nature approach and home schooling on their remote property, which has no running water.
ππ£π¦π πΈπππ£πππͺ
On Thursday, a judge in the town of LβAquila upheld prosecutorsβ claims that the children were suffering from βserious harmβ owing to their parentsβ back-to-nature approach and home schooling on their remote property, which has no running water.
ππ£π¦π πΈπππ£πππͺ
π€¬37π€‘5π’2π1
This media is not supported in your browser
VIEW IN TELEGRAM
β‘13π―7π3π2
This media is not supported in your browser
VIEW IN TELEGRAM
π₯20β€8π6
This media is not supported in your browser
VIEW IN TELEGRAM
π€£12π1π1
I mentioned this system yesterday. Its 288kwh battery system. The array is 100' long. Here's a tour. https://www.youtube.com/watch?v=WySi9cdRg4g
YouTube
DIY High Voltage Battery Solar System with Solis S6-EH1P11.4K-H-US
HV Battery system totaling 260kWh, Solis S6 hybrid inverter S6-EH1P11.4K-H-US. Short overview of the system. Started working on longer in detail version but video would have been hours long.
β€5
I just watched a video on Sodium batteries. There's a lot of hype about them right now. They are good for low temperatures down to -20F but look at their discharge curve. The company making them even said the voltage range is so wide that they have to sell them with special inverters that can operate over a wide range of voltages.
π€4
Worked on the neighbor's solar arrays today. A week or two ago, we build one array out of three just to make sure I didn't miss anything on the CAD drawing. Yesterday we augered and installed 8 posts so the ends of the two additional arrays would ser firm today. Today we augered 28 holes and set 7 posts. Now the perimeter posts are done and we can eaily "grid off" the interior posts with a couple of string lines. 21 posts let to set and we are done with concrete.
For those playing along on the home game, each 60' long array holds 16 panels. These panels end up being just under 45" wide and once we add the gap between for panel clamps they are almost exactly 45". We put down 9 pairs of posts on 7'6" centers. The two rows are 4' apart. These panels are quite heavy and we're using 2-3/8" sched 40 fence posts which are also quite heavy. we are using 240lbs of concrete per leg as ballast. So thats 72 forty pound bags of concrete per array.
For those playing along on the home game, each 60' long array holds 16 panels. These panels end up being just under 45" wide and once we add the gap between for panel clamps they are almost exactly 45". We put down 9 pairs of posts on 7'6" centers. The two rows are 4' apart. These panels are quite heavy and we're using 2-3/8" sched 40 fence posts which are also quite heavy. we are using 240lbs of concrete per leg as ballast. So thats 72 forty pound bags of concrete per array.
π7
For what it's worth, there is no requirement to run your water supply lines level although many people will do that. Something to think about... if you slope the water supply lines it makes it easier to drain them if you should need to winterize your tiny house. So when drilling holes thru wall studs to run pex tubing, consider a valve at the high end to allow air in, a drain valve outside and slope all the pipes inside the walls
Also keep in mind that you want pipes to be biased toward the inside of a wall not against the outside wall. And be sure to stuff insulation between the pipes and the outer wall....
And... be sure to drink your ovaltine.
Also keep in mind that you want pipes to be biased toward the inside of a wall not against the outside wall. And be sure to stuff insulation between the pipes and the outer wall....
And... be sure to drink your ovaltine.
π9π7β€1
This media is not supported in your browser
VIEW IN TELEGRAM
W.....K....R....P turkey drop
π€£19π₯°1π€‘1
Here's the power draw for a heat pump water heater. It pulls about 400-500w most of the time. However if the tank gets really cold it'll use the heat pump AND electric heating elements. In this case, I swapped the 4500w elements for 1500w elements so when they are on they don't pull too hard on my inverters. It ran the electric heat for about 10 minutes this morning and went right back to heat pumping.