CVE Notify
19.5K subscribers
4 photos
229K links
Alert on the latest CVEs

Partner channel: @malwr
Download Telegram
๐Ÿšจ CVE-2019-15892
An issue was discovered in Varnish Cache before 6.0.4 LTS, and 6.1.x and 6.2.x before 6.2.1. An HTTP/1 parsing failure allows a remote attacker to trigger an assert by sending crafted HTTP/1 requests. The assert will cause an automatic restart with a clean cache, which makes it a Denial of Service attack.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2017-8807
vbf_stp_error in bin/varnishd/cache/cache_fetch.c in Varnish HTTP Cache 4.1.x before 4.1.9 and 5.x before 5.2.1 allows remote attackers to obtain sensitive information from process memory because a VFP_GetStorage buffer is larger than intended in certain circumstances involving -sfile Stevedore transient objects.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2013-0345
varnish 3.0.3 uses world-readable permissions for the /var/log/varnish/ directory and the log files in the directory, which allows local users to obtain sensitive information by reading the files. NOTE: some of these details are obtained from third party information.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2015-8852
Varnish 3.x before 3.0.7, when used in certain stacked installations, allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a header line terminated by a \r (carriage return) character in conjunction with multiple Content-Length headers in an HTTP request.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-28385
An issue was discovered in certain Verbatim drives through 2022-03-31. Due to missing integrity checks, an attacker can manipulate the content of the emulated CD-ROM drive (containing the Windows and macOS client software). The content of this emulated CD-ROM drive is stored as an ISO-9660 image in the hidden sectors of the USB drive, that can only be accessed using special IOCTL commands, or when installing the drive in an external disk enclosure. By manipulating this ISO-9660 image or replacing it with another one, an attacker is able to store malicious software on the emulated CD-ROM drive. This software may get executed by an unsuspecting victim when using the device. For example, an attacker with temporary physical access during the supply chain could program a modified ISO-9660 image on a device that always accepts an attacker-controlled password for unlocking the device. If the attacker later on gains access to the used USB drive, he can simply decrypt all contained user data. Storing arbitrary other malicious software is also possible. This affects Executive Fingerprint Secure SSD GDMSFE01-INI3637-C VER1.1 and Fingerprint Secure Portable Hard Drive Part Number #53650.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2013-4484
Varnish before 3.0.5 allows remote attackers to cause a denial of service (child-process crash and temporary caching outage) via a GET request with trailing whitespace characters and no URI.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2013-4090
Varnish HTTP cache before 3.0.4: ACL bug

๐ŸŽ–@cveNotify
๐Ÿ‘1
๐Ÿšจ CVE-2022-1791
The One Click Plugin Updater WordPress plugin through 2.4.14 does not have CSRF check in place when updating its settings, which could allow attackers to make a logged in admin change them via a CSRF attack and disable / hide the badge of the available updates and the related check.

๐ŸŽ–@cveNotify
๐Ÿ‘1
๐Ÿšจ CVE-2022-28452
Red Planet Laundry Management System 1.0 is vulnerable to SQL Injection.

๐ŸŽ–@cveNotify
๐Ÿ‘1
๐Ÿšจ CVE-2019-5076
An exploitable out-of-bounds write vulnerability exists in the igcore19d.dll PNG header-parser of the Accusoft ImageGear 19.3.0 library. A specially crafted PNG file can cause an out-of-bounds write, resulting in a remote code execution. An attacker needs to provide a malformed file to the viction to trigger the vulnerability.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2019-5071
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2019-5072
An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2019-5083
An exploitable out-of-bounds write vulnerability exists in the igcore19d.dll TIFdecodethunderscan function of Accusoft ImageGear 19.3.0 library. A specially crafted TIFF file can cause an out of bounds write, resulting in a remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32349
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/classes/Master.php?f=delete_patient_history.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32339
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/admin/doctors/view_doctor.php?id=.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32344
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/classes/Master.php?f=delete_patient.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32343
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via hprms/admin/room_types/manage_room_type.php?id=.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32342
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/admin/room_types/view_room_type.php?id=.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32341
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/admin/?page=user/manage_user&id=.

๐ŸŽ–@cveNotify
๐Ÿšจ CVE-2022-32340
Hospital's Patient Records Management System v1.0 is vulnerable to SQL Injection via /hprms/admin/?page=patients/view_patient&id=.

๐ŸŽ–@cveNotify