π¨ CVE-2021-34770
A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) protocol processing of Cisco IOS XE Software for Cisco Catalyst 9000 Family Wireless Controllers could allow an unauthenticated, remote attacker to execute arbitrary code with administrative privileges or cause a denial of service (DoS) condition on an affected device. The vulnerability is due to a logic error that occurs during the validation of CAPWAP packets. An attacker could exploit this vulnerability by sending a crafted CAPWAP packet to an affected device. A successful exploit could allow the attacker to execute arbitrary code with administrative privileges or cause the affected device to crash and reload, resulting in a DoS condition.
π@cveNotify
A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) protocol processing of Cisco IOS XE Software for Cisco Catalyst 9000 Family Wireless Controllers could allow an unauthenticated, remote attacker to execute arbitrary code with administrative privileges or cause a denial of service (DoS) condition on an affected device. The vulnerability is due to a logic error that occurs during the validation of CAPWAP packets. An attacker could exploit this vulnerability by sending a crafted CAPWAP packet to an affected device. A successful exploit could allow the attacker to execute arbitrary code with administrative privileges or cause the affected device to crash and reload, resulting in a DoS condition.
π@cveNotify
Cisco
Cisco Security Advisory: Cisco IOS XE Software for Catalyst 9000 Family Wireless Controllers CAPWAP Remote Code Execution Vulnerability
A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) protocol processing of Cisco IOS XE Software for Cisco Catalyst 9000 Family Wireless Controllers could allow an unauthenticated, remote attacker to execute arbitrary code withβ¦
π¨ CVE-2025-20169
A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.
This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition.
This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system.
π@cveNotify
A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.
This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition.
This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system.
π@cveNotify
Cisco
Cisco Security Advisory: Cisco IOS, IOS XE, and IOS XR Software SNMP Denial of Service Vulnerabilities
Multiple vulnerabilities in the Simple Network Management Protocol (SNMP) subsystem of Cisco IOS Software, Cisco IOS XE Software, and Cisco IOS XR Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affectedβ¦
π₯1
π¨ CVE-2025-21801
In the Linux kernel, the following vulnerability has been resolved:
net: ravb: Fix missing rtnl lock in suspend/resume path
Fix the suspend/resume path by ensuring the rtnl lock is held where
required. Calls to ravb_open, ravb_close and wol operations must be
performed under the rtnl lock to prevent conflicts with ongoing ndo
operations.
Without this fix, the following warning is triggered:
[ 39.032969] =============================
[ 39.032983] WARNING: suspicious RCU usage
[ 39.033019] -----------------------------
[ 39.033033] drivers/net/phy/phy_device.c:2004 suspicious
rcu_dereference_protected() usage!
...
[ 39.033597] stack backtrace:
[ 39.033613] CPU: 0 UID: 0 PID: 174 Comm: python3 Not tainted
6.13.0-rc7-next-20250116-arm64-renesas-00002-g35245dfdc62c #7
[ 39.033623] Hardware name: Renesas SMARC EVK version 2 based on
r9a08g045s33 (DT)
[ 39.033628] Call trace:
[ 39.033633] show_stack+0x14/0x1c (C)
[ 39.033652] dump_stack_lvl+0xb4/0xc4
[ 39.033664] dump_stack+0x14/0x1c
[ 39.033671] lockdep_rcu_suspicious+0x16c/0x22c
[ 39.033682] phy_detach+0x160/0x190
[ 39.033694] phy_disconnect+0x40/0x54
[ 39.033703] ravb_close+0x6c/0x1cc
[ 39.033714] ravb_suspend+0x48/0x120
[ 39.033721] dpm_run_callback+0x4c/0x14c
[ 39.033731] device_suspend+0x11c/0x4dc
[ 39.033740] dpm_suspend+0xdc/0x214
[ 39.033748] dpm_suspend_start+0x48/0x60
[ 39.033758] suspend_devices_and_enter+0x124/0x574
[ 39.033769] pm_suspend+0x1ac/0x274
[ 39.033778] state_store+0x88/0x124
[ 39.033788] kobj_attr_store+0x14/0x24
[ 39.033798] sysfs_kf_write+0x48/0x6c
[ 39.033808] kernfs_fop_write_iter+0x118/0x1a8
[ 39.033817] vfs_write+0x27c/0x378
[ 39.033825] ksys_write+0x64/0xf4
[ 39.033833] __arm64_sys_write+0x18/0x20
[ 39.033841] invoke_syscall+0x44/0x104
[ 39.033852] el0_svc_common.constprop.0+0xb4/0xd4
[ 39.033862] do_el0_svc+0x18/0x20
[ 39.033870] el0_svc+0x3c/0xf0
[ 39.033880] el0t_64_sync_handler+0xc0/0xc4
[ 39.033888] el0t_64_sync+0x154/0x158
[ 39.041274] ravb 11c30000.ethernet eth0: Link is Down
π@cveNotify
In the Linux kernel, the following vulnerability has been resolved:
net: ravb: Fix missing rtnl lock in suspend/resume path
Fix the suspend/resume path by ensuring the rtnl lock is held where
required. Calls to ravb_open, ravb_close and wol operations must be
performed under the rtnl lock to prevent conflicts with ongoing ndo
operations.
Without this fix, the following warning is triggered:
[ 39.032969] =============================
[ 39.032983] WARNING: suspicious RCU usage
[ 39.033019] -----------------------------
[ 39.033033] drivers/net/phy/phy_device.c:2004 suspicious
rcu_dereference_protected() usage!
...
[ 39.033597] stack backtrace:
[ 39.033613] CPU: 0 UID: 0 PID: 174 Comm: python3 Not tainted
6.13.0-rc7-next-20250116-arm64-renesas-00002-g35245dfdc62c #7
[ 39.033623] Hardware name: Renesas SMARC EVK version 2 based on
r9a08g045s33 (DT)
[ 39.033628] Call trace:
[ 39.033633] show_stack+0x14/0x1c (C)
[ 39.033652] dump_stack_lvl+0xb4/0xc4
[ 39.033664] dump_stack+0x14/0x1c
[ 39.033671] lockdep_rcu_suspicious+0x16c/0x22c
[ 39.033682] phy_detach+0x160/0x190
[ 39.033694] phy_disconnect+0x40/0x54
[ 39.033703] ravb_close+0x6c/0x1cc
[ 39.033714] ravb_suspend+0x48/0x120
[ 39.033721] dpm_run_callback+0x4c/0x14c
[ 39.033731] device_suspend+0x11c/0x4dc
[ 39.033740] dpm_suspend+0xdc/0x214
[ 39.033748] dpm_suspend_start+0x48/0x60
[ 39.033758] suspend_devices_and_enter+0x124/0x574
[ 39.033769] pm_suspend+0x1ac/0x274
[ 39.033778] state_store+0x88/0x124
[ 39.033788] kobj_attr_store+0x14/0x24
[ 39.033798] sysfs_kf_write+0x48/0x6c
[ 39.033808] kernfs_fop_write_iter+0x118/0x1a8
[ 39.033817] vfs_write+0x27c/0x378
[ 39.033825] ksys_write+0x64/0xf4
[ 39.033833] __arm64_sys_write+0x18/0x20
[ 39.033841] invoke_syscall+0x44/0x104
[ 39.033852] el0_svc_common.constprop.0+0xb4/0xd4
[ 39.033862] do_el0_svc+0x18/0x20
[ 39.033870] el0_svc+0x3c/0xf0
[ 39.033880] el0t_64_sync_handler+0xc0/0xc4
[ 39.033888] el0t_64_sync+0x154/0x158
[ 39.041274] ravb 11c30000.ethernet eth0: Link is Down
π@cveNotify
π¨ CVE-2025-21802
In the Linux kernel, the following vulnerability has been resolved:
net: hns3: fix oops when unload drivers paralleling
When unload hclge driver, it tries to disable sriov first for each
ae_dev node from hnae3_ae_dev_list. If user unloads hns3 driver at
the time, because it removes all the ae_dev nodes, and it may cause
oops.
But we can't simply use hnae3_common_lock for this. Because in the
process flow of pci_disable_sriov(), it will trigger the remove flow
of VF, which will also take hnae3_common_lock.
To fixes it, introduce a new mutex to protect the unload process.
π@cveNotify
In the Linux kernel, the following vulnerability has been resolved:
net: hns3: fix oops when unload drivers paralleling
When unload hclge driver, it tries to disable sriov first for each
ae_dev node from hnae3_ae_dev_list. If user unloads hns3 driver at
the time, because it removes all the ae_dev nodes, and it may cause
oops.
But we can't simply use hnae3_common_lock for this. Because in the
process flow of pci_disable_sriov(), it will trigger the remove flow
of VF, which will also take hnae3_common_lock.
To fixes it, introduce a new mutex to protect the unload process.
π@cveNotify
π¨ CVE-2025-21826
In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_tables: reject mismatching sum of field_len with set key length
The field length description provides the length of each separated key
field in the concatenation, each field gets rounded up to 32-bits to
calculate the pipapo rule width from pipapo_init(). The set key length
provides the total size of the key aligned to 32-bits.
Register-based arithmetics still allows for combining mismatching set
key length and field length description, eg. set key length 10 and field
description [ 5, 4 ] leading to pipapo width of 12.
π@cveNotify
In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_tables: reject mismatching sum of field_len with set key length
The field length description provides the length of each separated key
field in the concatenation, each field gets rounded up to 32-bits to
calculate the pipapo rule width from pipapo_init(). The set key length
provides the total size of the key aligned to 32-bits.
Register-based arithmetics still allows for combining mismatching set
key length and field length description, eg. set key length 10 and field
description [ 5, 4 ] leading to pipapo width of 12.
π@cveNotify
π¨ CVE-2025-7329
A Stored Cross-Site Scripting security issue exists in the affected product that could potentially allow a malicious user to view and modify sensitive data or make the webpage unavailable. The vulnerability stems from missing special character filtering and encoding. Successful exploitation requires an attacker to be able to update configuration fields behind admin login.
π@cveNotify
A Stored Cross-Site Scripting security issue exists in the affected product that could potentially allow a malicious user to view and modify sensitive data or make the webpage unavailable. The vulnerability stems from missing special character filtering and encoding. Successful exploitation requires an attacker to be able to update configuration fields behind admin login.
π@cveNotify
Rockwell Automation
SD1756 | Security Advisory | Rockwell Automation | US
Comms - 1783-NATR Multiple Vulnerabilities
π¨ CVE-2025-7330
A cross-site request forgery security issue exists in the product and version listed. The vulnerability stems from missing CSRF checks on the impacted form. This allows for unintended configuration modification if an attacker can convince a logged in admin to visit a crafted link.
π@cveNotify
A cross-site request forgery security issue exists in the product and version listed. The vulnerability stems from missing CSRF checks on the impacted form. This allows for unintended configuration modification if an attacker can convince a logged in admin to visit a crafted link.
π@cveNotify
Rockwell Automation
SD1756 | Security Advisory | Rockwell Automation | US
Comms - 1783-NATR Multiple Vulnerabilities
π¨ CVE-2025-55688
Use after free in Windows PrintWorkflowUserSvc allows an authorized attacker to elevate privileges locally.
π@cveNotify
Use after free in Windows PrintWorkflowUserSvc allows an authorized attacker to elevate privileges locally.
π@cveNotify
π¨ CVE-2011-10035
Nagios XI versions prior to 2011R1.9 contain privilege escalation vulnerabilities in the scripts that install or update system crontab entries. Due to time-of-check/time-of-use race conditions and missing synchronization or final-path validation, a local low-privileged user could manipulate filesystem state during crontab installation to influence the files or commands executed with elevated privileges, resulting in execution with higher privileges.
π@cveNotify
Nagios XI versions prior to 2011R1.9 contain privilege escalation vulnerabilities in the scripts that install or update system crontab entries. Due to time-of-check/time-of-use race conditions and missing synchronization or final-path validation, a local low-privileged user could manipulate filesystem state during crontab installation to influence the files or commands executed with elevated privileges, resulting in execution with higher privileges.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2011-10036
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the handling of the "backend_url" JavaScript link. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the handling of the "backend_url" JavaScript link. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2011-10037
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the handling of xiwindow variables used to build permalinks in the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the handling of xiwindow variables used to build permalinks in the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2011-10038
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the recurring downtime script of the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the recurring downtime script of the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2011-10039
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the Alert Heatmap report and the βMy Reportsβ listing of the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the Alert Heatmap report and the βMy Reportsβ listing of the web interface. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2011-10040
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the link-handling functions used by status and report pages. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios XI versions prior to 2011R1.9 are vulnerable to cross-site scripting (XSS) via the link-handling functions used by status and report pages. Insufficient validation or escaping of user-supplied input may allow an attacker to inject and execute arbitrary script in the context of a victim's browser.
π@cveNotify
Nagios Enterprises
Nagios XI Changelog | Nagios Enterprises
Full visibility into your IT infrastructure with monitoring, alerting, and dashboards in one place.
π¨ CVE-2024-39097
There is an Open Redirect vulnerability in Gnuboard v6.0.4 and below via the `url` parameter in login path.
π@cveNotify
There is an Open Redirect vulnerability in Gnuboard v6.0.4 and below via the `url` parameter in login path.
π@cveNotify
Gist
CVE-2024-39097.md
GitHub Gist: instantly share code, notes, and snippets.
π¨ CVE-2025-57353
The Runtime components of messageformat package for Node.js before 3.0.2 contain a prototype pollution vulnerability. Due to insufficient validation of nested message keys during the processing of message data, an attacker can manipulate the prototype chain of JavaScript objects by providing specially crafted input. This can result in the injection of arbitrary properties into the Object.prototype, potentially leading to denial of service conditions or unexpected application behavior. The vulnerability allows attackers to alter the prototype of base objects, impacting all subsequent object instances throughout the application's lifecycle.
π@cveNotify
The Runtime components of messageformat package for Node.js before 3.0.2 contain a prototype pollution vulnerability. Due to insufficient validation of nested message keys during the processing of message data, an attacker can manipulate the prototype chain of JavaScript objects by providing specially crafted input. This can result in the injection of arbitrary properties into the Object.prototype, potentially leading to denial of service conditions or unexpected application behavior. The vulnerability allows attackers to alter the prototype of base objects, impacting all subsequent object instances throughout the application's lifecycle.
π@cveNotify
GitHub
PoCs/JavaScript/prototype-pollution/CVE-2025-57353 at main Β· OrangeShieldInfos/PoCs
Collection of Proof-of-Concepts. Contribute to OrangeShieldInfos/PoCs development by creating an account on GitHub.
π¨ CVE-2025-27208
A reflected Cross-Site Scripting (XSS) vulnerability has been identified in Revive Adserver version 5.5.2. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code in the context of the victim's browser. The session cookie cannot be accessed, but a number of other operations could be performed.
The vulnerability is present in the admin-search.php file and can be exploited via the compact parameter.
π@cveNotify
A reflected Cross-Site Scripting (XSS) vulnerability has been identified in Revive Adserver version 5.5.2. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code in the context of the victim's browser. The session cookie cannot be accessed, but a number of other operations could be performed.
The vulnerability is present in the admin-search.php file and can be exploited via the compact parameter.
π@cveNotify
HackerOne
Revive Adserver disclosed on HackerOne: Reflected Cross-Site...
A reflected Cross-Site Scripting (XSS) vulnerability has been identified in Revive Adserver version 5.5.2. This vulnerability allows an attacker to inject malicious JavaScript code into the...
π¨ CVE-2025-48980
In Brave Browser Desktop versions prior to 1.83.10 that have the split view feature enabled, the "Open Link in Split View" context menu item did not respect the SameSite cookie attribute. Therefore SameSite=Strict cookies would be sent on a cross-site navigation using this method.
π@cveNotify
In Brave Browser Desktop versions prior to 1.83.10 that have the split view feature enabled, the "Open Link in Split View" context menu item did not respect the SameSite cookie attribute. Therefore SameSite=Strict cookies would be sent on a cross-site navigation using this method.
π@cveNotify
HackerOne
Brave Software disclosed on HackerOne: SameSite restrictions are...
## Summary:
hello, Brave team.
There are cases where the SameSite policy is being bypassed, and I would like to report them.
When a user left-clicks a link in a cross-domain context and selects...
hello, Brave team.
There are cases where the SameSite policy is being bypassed, and I would like to report them.
When a user left-clicks a link in a cross-domain context and selects...
π¨ CVE-2025-48982
This vulnerability in Veeam Agent for Microsoft Windows allows for Local Privilege Escalation if a system administrator is tricked into restoring a malicious file.
π@cveNotify
This vulnerability in Veeam Agent for Microsoft Windows allows for Local Privilege Escalation if a system administrator is tricked into restoring a malicious file.
π@cveNotify
π¨ CVE-2025-48983
A vulnerability in the Mount service of Veeam Backup & Replication, which allows for remote code execution (RCE) on the Backup infrastructure hosts by an authenticated domain user.
π@cveNotify
A vulnerability in the Mount service of Veeam Backup & Replication, which allows for remote code execution (RCE) on the Backup infrastructure hosts by an authenticated domain user.
π@cveNotify
π¨ CVE-2025-23050
QLowEnergyController in Qt before 6.8.2 mishandles malformed Bluetooth ATT commands, leading to an out-of-bounds read (or division by zero). This is fixed in 5.15.19, 6.5.9, and 6.8.2.
π@cveNotify
QLowEnergyController in Qt before 6.8.2 mishandles malformed Bluetooth ATT commands, leading to an out-of-bounds read (or division by zero). This is fixed in 5.15.19, 6.5.9, and 6.8.2.
π@cveNotify