🛡 Cybersecurity & Privacy 🛡 - News
25.8K subscribers
89.2K links
🗞 The finest daily news on cybersecurity and privacy.

🔔 Daily releases.

💻 Is your online life secure?

📩 lalilolalo.dev@gmail.com
Download Telegram
‼ CVE-2021-40415 ‼

An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. In cgi_check_ability the Format API does not have a specific case, the user permission will default to 7. This will give non-administrative users the possibility to format the SD card and reboot the device.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40340 ‼

Information Exposure vulnerability in Hitachi Energy LinkOne application, due to a misconfiguration in the ASP server exposes server and ASP.net information, an attacker that manages to exploit this vulnerability can use the exposed information as a reconnaissance for further exploitation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-22992 ‼

A command injection remote code execution vulnerability was discovered on Western Digital My Cloud Devices that could allow an attacker to execute arbitrary system commands on the device. The vulnerability was addressed by escaping individual arguments to shell functions coming from user input.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-22826 ‼

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40411 ‼

An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [6] the dns_data->dns2 variable, that has the value of the dns2 parameter provided through the SetLocalLink API, is not validated properly. This would lead to an OS command injection.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-21217 ‼

An out-of-bounds write vulnerability exists in the device TestEmail functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted network request can lead to an out-of-bounds write. An attacker can send an HTTP request to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-21199 ‼

An information disclosure vulnerability exists due to the hardcoded TLS key of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information. An attacker can perform a man-in-the-middle attack to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-22994 ‼

A remote code execution vulnerability was discovered on Western Digital My Cloud devices where an attacker could trick a NAS device into loading through an unsecured HTTP call. This was a result insufficient verification of calls to the device. The vulnerability was addressed by disabling checks for internet connectivity using HTTP.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-21796 ‼

A memory corruption vulnerability exists in the netserver parse_command_list functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to an out-of-bounds write. An attacker can send an HTTP request to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40416 ‼

An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. All the Get APIs that are not included in cgi_check_ability are already executable by any logged-in users. An attacker can send an HTTP request to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40410 ‼

An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [4] the dns_data->dns1 variable, that has the value of the dns1 parameter provided through the SetLocal API, is not validated properly. This would lead to an OS command injection.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-22993 ‼

A limited SSRF vulnerability was discovered on Western Digital My Cloud devices that could allow an attacker to impersonate a server and reach any page on the server by bypassing access controls. The vulnerability was addressed by creating a whitelist for valid parameters.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-22815 ‼

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40414 ‼

An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. The SetMdAlarm API sets the movement detection parameters, giving the ability to set the sensitivity of the camera per a range of hours, and which of the camera spaces to ignore when considering movement detection. Because in cgi_check_ability the SetMdAlarm API does not have a specific case, the user permission will default to 7. This will give non-administrative users the possibility to change the movement detection parameters.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40412 ‼

An OScommand injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [8] the devname variable, that has the value of the name parameter provided through the SetDevName API, is not validated properly. This would lead to an OS command injection.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-22812 ‼

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-40404 ‼

An authentication bypass vulnerability exists in the cgiserver.cgi Login functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-21134 ‼

A firmware update vulnerability exists in the "update" firmware checks functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to firmware update. An attacker can send a sequence of requests to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2022-21236 ‼

An information disclosure vulnerability exists due to a web server misconfiguration in the Reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-22807 ‼

A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior

📖 Read

via "National Vulnerability Database".
‼ CVE-2021-22825 ‼

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)

📖 Read

via "National Vulnerability Database".