‼ CVE-2022-22294 ‼
📖 Read
via "National Vulnerability Database".
A SQL injection vulnerability exists in ZFAKA<=1.43 which an attacker can use to complete SQL injection in the foreground and add a background administrator account.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-45898 ‼
📖 Read
via "National Vulnerability Database".
SuiteCRM before 7.12.3 and 8.x before 8.0.2 allows local file inclusion.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-45897 ‼
📖 Read
via "National Vulnerability Database".
SuiteCRM before 7.12.3 and 8.x before 8.0.2 allows remote code execution.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-40395 ‼
📖 Read
via "National Vulnerability Database".
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-45899 ‼
📖 Read
via "National Vulnerability Database".
SuiteCRM before 7.12.3 and 8.x before 8.0.2 allows PHAR deserialization that can lead to remote code execution.📖 Read
via "National Vulnerability Database".
🔏 Friday Five 1/28 🔏
📖 Read
via "".
The Linux PolicyKit bug, $770 million lost in social media scams, and more - catch up on the infosec news of the week with the Friday Five!📖 Read
via "".
‼ CVE-2021-40423 ‼
📖 Read
via "National Vulnerability Database".
A denial of service vulnerability exists in the cgiserver.cgi API command parser functionality of Reolink RLC-410W v3.0.0.136_20121102. A specially-crafted series of HTTP requests can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-22799 ‼
📖 Read
via "National Vulnerability Database".
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1📖 Read
via "National Vulnerability Database".
‼ CVE-2022-23727 ‼
📖 Read
via "National Vulnerability Database".
There is a privilege escalation vulnerability in some webOS TVs. Due to wrong setting environments, local attacker is able to perform specific operation to exploit this vulnerability. Exploitation may cause the attacker to obtain a higher privilege📖 Read
via "National Vulnerability Database".
‼ CVE-2021-22819 ‼
📖 Read
via "National Vulnerability Database".
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)📖 Read
via "National Vulnerability Database".
‼ CVE-2021-31567 ‼
📖 Read
via "National Vulnerability Database".
Authenticated (admin+) Arbitrary File Download vulnerability discovered in Download Monitor WordPress plugin (versions <= 4.4.6). The plugin allows arbitrary files, including sensitive configuration files such as wp-config.php, to be downloaded via the &downloadable_file_urls[0] parameter data. It's also possible to escape from the web server home directory and download any file within the OS.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-26264 ‼
📖 Read
via "National Vulnerability Database".
A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-40407 ‼
📖 Read
via "National Vulnerability Database".
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability.📖 Read
via "National Vulnerability Database".
‼ CVE-2016-3735 ‼
📖 Read
via "National Vulnerability Database".
Piwigo is image gallery software written in PHP. When a criteria is not met on a host, piwigo defaults to usingmt_rand in order to generate password reset tokens. mt_rand output can be predicted after recovering the seed used to generate it. This low an unauthenticated attacker to take over an account providing they know an administrators email address in order to be able to request password reset.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-22810 ‼
📖 Read
via "National Vulnerability Database".
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)📖 Read
via "National Vulnerability Database".
‼ CVE-2022-22938 ‼
📖 Read
via "National Vulnerability Database".
VMware Workstation (16.x prior to 16.2.2) and Horizon Client for Windows (5.x prior to 5.5.3) contains a denial-of-service vulnerability in the Cortado ThinPrint component. The issue exists in TrueType font parser. A malicious actor with access to a virtual machine or remote desktop may exploit this issue to trigger a denial-of-service condition in the Thinprint service running on the host machine where VMware Workstation or Horizon Client for Windows is installed.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-40409 ‼
📖 Read
via "National Vulnerability Database".
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->password variable, that has the value of the password parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-40415 ‼
📖 Read
via "National Vulnerability Database".
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. In cgi_check_ability the Format API does not have a specific case, the user permission will default to 7. This will give non-administrative users the possibility to format the SD card and reboot the device.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-40340 ‼
📖 Read
via "National Vulnerability Database".
Information Exposure vulnerability in Hitachi Energy LinkOne application, due to a misconfiguration in the ASP server exposes server and ASP.net information, an attacker that manages to exploit this vulnerability can use the exposed information as a reconnaissance for further exploitation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26.📖 Read
via "National Vulnerability Database".
‼ CVE-2022-22992 ‼
📖 Read
via "National Vulnerability Database".
A command injection remote code execution vulnerability was discovered on Western Digital My Cloud Devices that could allow an attacker to execute arbitrary system commands on the device. The vulnerability was addressed by escaping individual arguments to shell functions coming from user input.📖 Read
via "National Vulnerability Database".
‼ CVE-2021-22826 ‼
📖 Read
via "National Vulnerability Database".
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions📖 Read
via "National Vulnerability Database".