❌ Emerging Ransomware Targets Photos, Videos on Android Devices ❌
📖 Read
via "Threatpost".
The CryCryptor malware strain is a brand-new family of threats, leveraging COVID-19 to spread.📖 Read
via "Threatpost".
Threat Post
Emerging Ransomware Targets Photos, Videos on Android Devices
The CryCryptor malware strain is a brand-new family of threats, leveraging COVID-19 to spread.
ATENTION‼ New - CVE-2020-11095
📖 Read
via "National Vulnerability Database".
In FreeRDP before version 2.1.2, an out of bound reads occurs resulting in accessing a memory location that is outside of the boundaries of the static array PRIMARY_DRAWING_ORDER_FIELD_BYTES. This is fixed in version 2.1.2.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-11068
📖 Read
via "National Vulnerability Database".
In LoRaMac-node before 4.4.4, a reception buffer overflow can happen due to the received buffer size not being checked. This has been fixed in 4.4.4.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10740
📖 Read
via "National Vulnerability Database".
A vulnerability was found in Wildfly in versions before 20.0.0.Final, where a remote deserialization attack is possible in the Enterprise Application Beans(EJB) due to lack of validation/filtering capabilities in wildfly.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10736
📖 Read
via "National Vulnerability Database".
An authorization bypass vulnerability was found in Ceph versions 15.2.0 before 15.2.2, where the ceph-mon and ceph-mgr daemons do not properly restrict access, resulting in gaining access to unauthorized resources. This flaw allows an authenticated client to modify the configuration and possibly conduct further attacks.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10561
📖 Read
via "National Vulnerability Database".
An issue was discovered on Xiaomi Mi Jia ink-jet printer < 3.4.6_0138. Injecting parameters to ippserver through the web management background, resulting in command execution vulnerabilities.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10280
📖 Read
via "National Vulnerability Database".
The Apache server on port 80 that host the web interface is vulnerable to a DoS by spamming incomplete HTTP headers, effectively blocking the access to the dashboard.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10279
📖 Read
via "National Vulnerability Database".
MiR robot controllers (central computation unit) makes use of Ubuntu 16.04.2 an operating system, Thought for desktop uses, this operating system presents insecure defaults for robots. These insecurities include a way for users to escalate their access beyond what they were granted via file creation, access race conditions, insecure home directory configurations and defaults that facilitate Denial of Service (DoS) attacks.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10278
📖 Read
via "National Vulnerability Database".
The BIOS onboard MiR's Computer is not protected by password, therefore, it allows a Bad Operator to modify settings such as boot order. This can be leveraged by a Malicious operator to boot from a Live Image.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10277
📖 Read
via "National Vulnerability Database".
There is no mechanism in place to prevent a bad operator to boot from a live OS image, this can lead to extraction of sensible files (such as the shadow file) or privilege escalation by manually adding a new user with sudo privileges on the machine.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10276
📖 Read
via "National Vulnerability Database".
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10275
📖 Read
via "National Vulnerability Database".
The access tokens for the REST API are directly derived from the publicly available default credentials for the web interface. Given a USERNAME and a PASSWORD, the token string is generated directly with base64(USERNAME:sha256(PASSWORD)). An unauthorized attacker inside the network can use the default credentials to compute the token and interact with the REST API to exfiltrate, infiltrate or delete data.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10274
📖 Read
via "National Vulnerability Database".
The access tokens for the REST API are directly derived (sha256 and base64 encoding) from the publicly available default credentials from the Control Dashboard (refer to CVE-2020-10270 for related flaws). This flaw in combination with CVE-2020-10273 allows any attacker connected to the robot networks (wired or wireless) to exfiltrate all stored data (e.g. indoor mapping images) and associated metadata from the robot's database.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10273
📖 Read
via "National Vulnerability Database".
MiR controllers across firmware versions 2.8.1.1 and before do not encrypt or protect in any way the intellectual property artifacts installed in the robots. This flaw allows attackers with access to the robot or the robot network (while in combination with other flaws) to retrieve and easily exfiltrate all installed intellectual property and data.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10272
📖 Read
via "National Vulnerability Database".
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10271
📖 Read
via "National Vulnerability Database".
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10270
📖 Read
via "National Vulnerability Database".
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2020-10269
📖 Read
via "National Vulnerability Database".
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2019-3865
📖 Read
via "National Vulnerability Database".
A vulnerability was found in quay-2, where a stored XSS vulnerability has been found in the super user function of quay. Attackers are able to use the name field of service key to inject scripts and make it run when admin users try to change the name.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2019-20409
📖 Read
via "National Vulnerability Database".
The way in which velocity templates were used in Atlassian Jira Server and Data Center prior to version 8.8.0 allowed remote attackers to gain remote code execution if they were able to exploit a server side template injection vulnerability.📖 Read
via "National Vulnerability Database".
ATENTION‼ New - CVE-2019-14894
📖 Read
via "National Vulnerability Database".
A flaw was found in the CloudForms management engine version 5.10 and CloudForms management version 5.11, which triggered remote code execution through NFS schedule backup. An attacker logged into the management console could use this flaw to execute arbitrary shell commands on the CloudForms server as root.📖 Read
via "National Vulnerability Database".