pressure balanced expansion joint DN800 on a gas turbine
The four tie bars all were broken during piping running.
Exhaust system with bellows expansion joint and exhaust cooling system for a luxury yacht. Particular customer specification: very high acoustic and vibration insulation.
Exhaust system with bellows expansion joint and exhaust cooling system inc. complete insulation.
Pipe is anchored to support it and to stabilize the expansion joint. Pipe leg anchor should be used for horizontal suction piping, while an “H-Frame” should be used to anchor vertical discharge where
Anchors should be bolted to floor and welded to pipe before installation of expansion joint.
All anchors and guides should be installed according to EJMA standards.
Lateral expansion joint type U111M
in a GRP sea water line
NB 3000, 6 bar, 60°C
Universal expansion joint type U110A installed in a cooling tower of a coal fired power plant
NB 3100, 4 bar, movements in all directions +/- 40 mm
Type U111M Lateral expansion joints
in the form of “dismantling joints”
in the cooling water system of a coal-fired power plant
NB 2000, +4/–0.9 bar
Expansion joint presetting
In order to increase axial movement, the expansion joint can be presetted to its maximum extension during installation. For expansion joints with swivel flange there is a risk during the extension that the sealing bulge will spring from the groove of the backing flange. If presettings of more than 10 mm are needed, a flange connection will need to be disconnected at another location. Now the expansion joint can be installed relaxed and the flange disconnection sites that were opened before can be closed again.
n order to increase lateral movement, the expansion joint can be presetted to its maximum lateral displace- ment against the direction of movement during installation. During operation, it will move back to the opposite side through the zero point. In this way, the lateral movement can be increased by up to 100%. For expansion joints with swivel flange there is a risk during displacement that the sealing bulge will spring from the groove of the backing flange. If presettings of more than 5 mm are needed, a flange connection will need to be disconnected at another location. Now the expansion joint can be installed relaxed and the flange disconnection sites that were opened before can be closed again.
Universal expansion joint, type U110A
on the supply pumps in a paper mill
NB 80 – NB 350, 10 bar
Small-Bore Connections⬇️
Small-bore connections, also called branch connections, to the main process piping represent the most common vibration problem on rotating and reciprocating machinery and associated process piping.
Small-bore connection design assessment and field vibration testing are strongly recommended to avoid piping integrity risks.
Piping vibration and fatigue can account for up to 20% of hydrocarbon releases; and a large portion of those are due to failure of small-bore connections per Energy Institute, 2008, Guidelines for the avoidance of vibration induced fatigue failure, (AVIFF). Hydrocarbon emissions can lead to fire, explosions, injuries, property and environmental damage, and penalties.
A small-bore connection (SBC) is generally defined as a branched connection on mainline piping that has a nominal diameter 2” (DN 50) and smaller, including connections that have a branch pipe to mainline pipe ratio of less than 10%, and excluding connections that have a ratio of greater than 25% (see Figure below). Note that “mainline piping” could also describe equipment like a vessel or cooler to which the SBC is attached.
Small-bore piping (SBP) is defined as the piping attached to the small-bore connection, extending until the effect of the mainline piping vibration is negligible (typically, the nearest support or brace), as shown in the illustration below.
Small-bore connections
Field audit of small-bore connections
Cracked vessel due to SBC (blind flange)