This media is not supported in your browser
VIEW IN TELEGRAM
π24π15β€2
This media is not supported in your browser
VIEW IN TELEGRAM
Axial magnetic pump coupler. Grundfos uses a radial version of the same concept.
π18β‘10π4β€1π€―1
Forwarded from Working Men Memes (ππΆπππ)
This media is not supported in your browser
VIEW IN TELEGRAM
π₯°25β€3π1
Media is too big
VIEW IN TELEGRAM
Florida is one state where you are required to be connected to power. That means a monthly minimum bill. They also want to charge solar grid tied system people an additional $25 a month extra βto cover the cost of providing service to low usage customers.β Wait wasnβt that what the min bill is for???
Folks as power companies are changing these grid tied rules you are better off to simply install a system with batteries that doesnβt sell power. Just use the grid to charge batteries if you need a little energy.
Folks as power companies are changing these grid tied rules you are better off to simply install a system with batteries that doesnβt sell power. Just use the grid to charge batteries if you need a little energy.
β‘23π―12π€¬7π€£3β€1π1
Forwarded from South Africa Reports
π§π Orania's new 4.8 MWh battery arrived this morning
Once installed, Orania will be the only town in South Africa without loadshedding from 06:00 to 22:00
Once installed, Orania will be the only town in South Africa without loadshedding from 06:00 to 22:00
β‘35π6π2π1
Here's a heat exchanger for a geothermal heat pump... in a pond. https://www.youtube.com/watch?v=jYS2wPWPEPI
YouTube
DROPPING a Giant Heat Exchanger in Our Pond for Free Heat!
Tractor Time with Tim is installing a Slim Jim heat exchanger in the pond for the geothermal system for the Dream Shop! The geothermal system will provide heating and cooling for the shop and office creating a sustainable hvac system. The team explains theβ¦
π₯4π1
Forwarded from Working Men Memes (Atomic Rooster)
This media is not supported in your browser
VIEW IN TELEGRAM
She shoots better than half of you
π18β€14π5π5π₯°3π₯1
Forwarded from Resistance awakening β¨πβ¨ (Badger)
Media is too big
VIEW IN TELEGRAM
Please open Telegram to view this post
VIEW IN TELEGRAM
π―30π8π₯4β€2
Forwarded from Ashton
A cowboy friend of mine, half my age, but already twice the man has a saying. He says it a lot.
"You can steal my money, and I can probably forgive you. You can take a cow, and I'll figure you for hungry, and we'll work something out. But if you steal my time? If you steal that, God help you cause there ain't no forgiveness down that road with me. Don't take anything I can't replace, or it won't work out well for either of us."
That's a lesson I wish I'd learned at his age.
"You can steal my money, and I can probably forgive you. You can take a cow, and I'll figure you for hungry, and we'll work something out. But if you steal my time? If you steal that, God help you cause there ain't no forgiveness down that road with me. Don't take anything I can't replace, or it won't work out well for either of us."
That's a lesson I wish I'd learned at his age.
π29π―12π₯7β€3β‘3
A local guy came by yesterday to consult about his solar setup. He revealed to me that heβd been connecting the pv wires inside a jbox and had stabbed himself in the finger with 360vdc.
The solution for this is to disconnect any two panels in the string, do the work and then reconnect them.
The solution for this is to disconnect any two panels in the string, do the work and then reconnect them.
π€―4β€1
A word about generators and solar. If your system is grid tied or you otherwise use AC coupled inverters, make sure your generator idles at 3720rpm 62hz (3120rpm 52hz in Europe).
The reason for this is that when grid tied inverters see 60hz (50hz) they will synchronize with it and make all the power they can. They will happily backfeed your generator and harm it.
If the generator is idling at 62hz (52hz eu) the solar inverters will see this as either "out of spec" or "make 0 power" and not back feed your generator.
Older grid tie inverters will not sync when the frequency is >60.5hz. Newer grid tie inverters will make full power up until 61hz and throttle back power as the frequency rises to 62hz.
Attached is a screen shot of my battery inverter throttling the grid tie inverters.
The reason for this is that when grid tied inverters see 60hz (50hz) they will synchronize with it and make all the power they can. They will happily backfeed your generator and harm it.
If the generator is idling at 62hz (52hz eu) the solar inverters will see this as either "out of spec" or "make 0 power" and not back feed your generator.
Older grid tie inverters will not sync when the frequency is >60.5hz. Newer grid tie inverters will make full power up until 61hz and throttle back power as the frequency rises to 62hz.
Attached is a screen shot of my battery inverter throttling the grid tie inverters.
π4β€1
Fire drill time:
Tonight while your wife and kids are watching TV, go outside to the highway. Approach your house as if you were going to rob it. Look at your house from an outsider's perspective. Could you look in the windows without anyone noticing? Could you have kicked in the back door? Think about how attractive a house with lights on would be after SHTF. Think about how far the smell of bbq can carry.
So how defensible is your house? How attractive is your house (in the wrong way).
Something to think about.
Tonight while your wife and kids are watching TV, go outside to the highway. Approach your house as if you were going to rob it. Look at your house from an outsider's perspective. Could you look in the windows without anyone noticing? Could you have kicked in the back door? Think about how attractive a house with lights on would be after SHTF. Think about how far the smell of bbq can carry.
So how defensible is your house? How attractive is your house (in the wrong way).
Something to think about.
π33π5β€1