Choosing Low Wattage Appliances for my Off-grid Solar Setup
It's not just about having enough panels and battery power to operate your off-grid home. Choosing the right appliances and checking how much power they will draw and making sure they are compatible with your electrical system is of paramount importance.β¦
π6β€1
I posted a few days about about running saws and drills that use brushed motors on 120v dc. I just revised that article to reflect some additional info.
Brushed βuniversal ACβ motors are series wound. That means the coil and the stator are in series with each other and oppose each other until they make a certain strength magnetic field. Until that magnetic field reaches its peak, they will draw more and more power. If the voltage is low they will draw more amps. Twice as many amps means 4x the heat. This is why long extension cords melt. Long cords mean less voltage at the far end and the motors draw more amps.
So donβt be afraid to feed them voltage just a hair over 120v.
https://t.me/OffTheGridOfficial/6681
Brushed βuniversal ACβ motors are series wound. That means the coil and the stator are in series with each other and oppose each other until they make a certain strength magnetic field. Until that magnetic field reaches its peak, they will draw more and more power. If the voltage is low they will draw more amps. Twice as many amps means 4x the heat. This is why long extension cords melt. Long cords mean less voltage at the far end and the motors draw more amps.
So donβt be afraid to feed them voltage just a hair over 120v.
https://t.me/OffTheGridOfficial/6681
Telegram
Off The Grid
You can run your hot water heater or other heaters directly off 120vDC or 240vDC if they are rated for 120vac or 240vac... BUT... the switches will fail. For example, the thermostat of a hot water heater will fail the first time every time. You must useβ¦
π5
This media is not supported in your browser
VIEW IN TELEGRAM
Raising daughters.
π22β€9π3π2π₯΄2
Preserving Food without Freezin - Deborah Madison.pdf
3.5 MB
π6β€1π1
My wife told me she'll slam my head into the keyboard if I don't get off the computer.
I'm not too worried.
I think she's just jokinsdnbfjadskbngfsjkgbsafgfsgadfgdfgdf
I'm not too worried.
I think she's just jokinsdnbfjadskbngfsjkgbsafgfsgadfgdfgdf
π€£70π16π₯΄4
This media is not supported in your browser
VIEW IN TELEGRAM
π16π₯΄8π5π3π€‘2
Off The Grid
Video
This is used for soundproofing but it also works for stopping thermal conductivity.
π15π€‘3π1π₯΄1
https://pvwatts.nrel.gov/pvwatts.php
You can plug your address into PVwatts, tell it the kW of solar panels, look in the advanced section and put in your DC-AC ratio, and it'll use historical cloud cover for your area to make predictions for solar production. How accurate is it? I plugged in my system and it gave me results broken down by month. December should see 100.55kWh per day and according to my own calculations, I'm averaging 99.59 per day since Dec 1. I'll call that a win.
Europeans: use this link https://re.jrc.ec.europa.eu/pvg_tools/en/
A note about DC - AC ratio. If you look under advanced parameters, you'll find DC to AC size ratio. One on my arrays has 19.5kw of solar with 15.8kw of inverters. That's 1.23. Another array has 11kw of solar with 6kw of inverters and that is 1.83. Be sure to select ground or roof mount and bifacial in the advanced section. Everything else is pretty much good to go.
You can plug your address into PVwatts, tell it the kW of solar panels, look in the advanced section and put in your DC-AC ratio, and it'll use historical cloud cover for your area to make predictions for solar production. How accurate is it? I plugged in my system and it gave me results broken down by month. December should see 100.55kWh per day and according to my own calculations, I'm averaging 99.59 per day since Dec 1. I'll call that a win.
Europeans: use this link https://re.jrc.ec.europa.eu/pvg_tools/en/
A note about DC - AC ratio. If you look under advanced parameters, you'll find DC to AC size ratio. One on my arrays has 19.5kw of solar with 15.8kw of inverters. That's 1.23. Another array has 11kw of solar with 6kw of inverters and that is 1.83. Be sure to select ground or roof mount and bifacial in the advanced section. Everything else is pretty much good to go.
pvwatts.nlr.gov
PVWatts - NREL
Estimates the energy production and cost of energy of grid-connected photovoltaic (PV) energy systems throughout the world
π€3π€¬1
Forwarded from The Deer Blind (EightyπCanadian)
This media is not supported in your browser
VIEW IN TELEGRAM
Orchard Drones. They're taking our jobs!
π€‘19π€¬8π€£5π3
Forwarded from Ancaipira
Here on this website you have everything you need to know and you can even contact them and they will guide you in the best possible way and they have spectacular micro hydroelectric plants, both for on grid (asynchronous) and off grid or hybrid systems with (permanent magnet generator)
https://h-hydro.com/
https://h-hydro.com/
Hartvigsen Hydro
Micro Hydro Power
We are a worldwide supplier of micro hydro components including turgo runners, housings, nozzles and generators.
β€8π3π€‘1
Media is too big
VIEW IN TELEGRAM
Parenting boys.... tricycle motors and curtain climbers
π―30β€10π6π₯΄2β‘1
https://www.youtube.com/shorts/1OKaC0hPxjc and don't forget to season the pan with some lard.
YouTube
Polishing Cast Iron
Source: Bviral
π€5π1π€¨1
Media is too big
VIEW IN TELEGRAM
Everyday carry kit from one of our folks in South Africa.
π12π8β€1
Forwarded from HickTown (Hammer)
This media is not supported in your browser
VIEW IN TELEGRAM
π25β€5π1
Amp Interruption Calculation_Tech_Lib_Electrical_Formulas.pdf
446 KB
Dont know who might need this, but here's the formula for calculating the amp interruption rating needed for a main breaker from your utility service. I wrote this spread sheet a few years ago. Originally my solar system had a shutoff that killed the backfeed from the solar inverters. But since I've reorganized my system, that switch has been bypassed. Next week I'll be routing my service entrance cabling from the meter base thru a 100amp lockable shut off switch. It is required by code to have a lockable shut off when backfeeding the grid. Since I can't separate my solar, I'll just separate the whole house.
Basically, at 25kva transformer can deliver 100amps @ 240vac but in the case of an arc fault, it could deliver 8000amps of surge. If you have a longer feeder like I do (275ft), resistance of the wires to the pole will limit that current. So my limit is 2916amps. This is well within the limits of the fused knife switch and the 1 AWG cable I'll be using.
Basically, at 25kva transformer can deliver 100amps @ 240vac but in the case of an arc fault, it could deliver 8000amps of surge. If you have a longer feeder like I do (275ft), resistance of the wires to the pole will limit that current. So my limit is 2916amps. This is well within the limits of the fused knife switch and the 1 AWG cable I'll be using.
π6