MCQ NO.1155 | IMA

Which of the following is not a detector used in Flame emission photometers?
Anonymous Quiz
14%
Photronic cell
22%
Photovoltaic cell
17%
Photoemissive tube
46%
Chromatogram
MCQ NO.1156 | IMA

The function of pressure regulators in emission system of flame photometer is to have a steady flame which is free from flickers.
Anonymous Quiz
78%
True
22%
False
MCQ NO.1157 | IMA

In Total consumption burner, only samples of particular droplet size will enter the burner.
Anonymous Quiz
69%
True
31%
False
MCQ NO.1158 | IMA

Phototubes are more sensitive than photovoltaic cells.
Anonymous Quiz
69%
True
31%
False
MCQ NO.1159 | IMA

Which of the following is not an application of Flame emission photometers?
Anonymous Quiz
27%
Analysis of biological fluids
32%
Determination of sodium, potassium in soil
21%
Determination of metals such as Mn, Cu
21%
Analysis of complex mixtures
MCQ NO.1169 | IMA

Which of the following is not an advantage of photovoltaic cell which is used as a detector in Flame emission photometers?
Anonymous Quiz
17%
Portable
28%
No external supply
36%
Robust in construction
19%
Does not show fatigue
MCQ NO.1161 | IMA

If Propane and air are used in burner how many °C temp. is produced ?
Anonymous Quiz
19%
1900°C
42%
2200°C
25%
2300°C
14%
2100°C
MCQ NO.1162 | IMA

Which of the following components of the X-ray fluorescent spectrometer induces fluorescent radiation?
Anonymous Quiz
25%
Excitation source
20%
Energy analyser
50%
X-ray spectrometer
5%
Detection System
MCQ NO.1163 | IMA

Why is a mono-energetic radiation source required in X-ray fluorescent spectrometer?
Anonymous Quiz
32%
To provide good sensitivity
32%
To provide high accuracy
20%
To provide a proper range
16%
To reduce unwanted background
MCQ NO.1164 | IMA

Which of the following does not make the X-ray tube nearly monochromatic?
Anonymous Quiz
20%
Transmission-anode X-ray tube
39%
Secondary fluorescence target
28%
Slit
13%
Filters
MCQ NO.1165 | IMA

Which of the following components make use of a thin metal foil to isolate a nearly mono-energetic excitation beam?
Anonymous Quiz
32%
Transmission-anode X-ray tube
32%
Secondary fluorescence target
23%
Slit
12%
Filters
MCQ NO.1165 | IMA

Energy dispersive system uses which of the following detectors?
Anonymous Quiz
17%
Optical detector
41%
Semiconductor detector
25%
Thermistor
16%
Bolometer
MCQ NO.1166 | IMA

In Energy dispersive system, the energy level and the number of pulses is related to which of the following?
Anonymous Quiz
14%
Amount of sample, element involved
41%
Element involved, concentration of the element
33%
Concentration of the element, element involved
12%
Number of atoms, amount of sample
MCQ. NO.1167 | IMA

The analysis of X-ray beam by diffraction is similar to spectrum analysis carried out with a diffraction grating.
Anonymous Quiz
76%
True
24%
False
MCQ NO.1168 | IMA

The crystal used as X-ray grating has _______ dimensional lattice arrays?
Anonymous Quiz
14%
One
39%
Two
40%
Three
7%
Four
MCQ NO.1169 | IMA

Which of the following can be done to avoid loss of intensities of X-rays due to absorption of long wavelength X-rays?
Anonymous Quiz
14%
Apparatus must be contained in a chamber
51%
Air in the chamber must be replaced by helium
23%
Inert gas atmosphere must be provided
11%
Proper slits must be used
MCQ NO.1170 | IMA

In curved crystal arrangement, angular velocity of the crystal is twice that of the detector.
Anonymous Quiz
76%
True
24%
False
MCQ NO.1171 | IMA

Which of the following is the disadvantage of silicon semiconductor detector?m
Anonymous Quiz
11%
Low stable
60%
Can be operated only at low temperatures
16%
Have low count-rate
13%
Low resolution