#IEC61850
The AMU is a Merging Unit in a digital substation which can publish messages over the substation process bus in compliance with the IEC 61850-9-2LE or IEC61869-9 standard. Data is published in the form of sampled values (SV) that comply with the light edition (LE) of the IEC 61850-9-2. And it has high accuracy time synchronization via PPS or IRIG-B, NTP, PTP1588, local clock or via its internal built-in GPS receiver. It is Complies with: IEC 61850-9-2LE, and IEC 61850 GOOSE messaging. Also complies with the new IEC 61869-9 standard.
@Elec_Engg
The AMU is a Merging Unit in a digital substation which can publish messages over the substation process bus in compliance with the IEC 61850-9-2LE or IEC61869-9 standard. Data is published in the form of sampled values (SV) that comply with the light edition (LE) of the IEC 61850-9-2. And it has high accuracy time synchronization via PPS or IRIG-B, NTP, PTP1588, local clock or via its internal built-in GPS receiver. It is Complies with: IEC 61850-9-2LE, and IEC 61850 GOOSE messaging. Also complies with the new IEC 61869-9 standard.
@Elec_Engg
#SIEMENS #REYROLLE
The 7SR18 is a numeric three phase differential protection used to detect in zone phase and earth faults. The relay is applied to overhead line and underground cable circuits as well as shorter circuits such as interconnectors.
https://elec-engg.com/reyrolle-7sr18/
@Elec_Engg
The 7SR18 is a numeric three phase differential protection used to detect in zone phase and earth faults. The relay is applied to overhead line and underground cable circuits as well as shorter circuits such as interconnectors.
https://elec-engg.com/reyrolle-7sr18/
@Elec_Engg
#SEL #Wiring_Diagram
🔹SEL 421 Wiring Diagram
🔸https://elec-engg.com/sel-421-wiring-connection/
@Elec_Engg
🔹SEL 421 Wiring Diagram
🔸https://elec-engg.com/sel-421-wiring-connection/
@Elec_Engg
#Substation
🔹Power Plant Switching Station (Switchyard)
🔸https://elec-engg.com/power-plant-switching-station-switchyard/
🔹Power Plant Switching Station (Switchyard)
🔸https://elec-engg.com/power-plant-switching-station-switchyard/
#Relay_Coordination #Relay_Setting
🔷Relay Coordination and setting for Substation (excel sheet + explanation)
🔸https://elec-engg.com/relay-coordination-and-setting-for-substation-excel-sheet-explanation/
@Elec_Engg
🔷Relay Coordination and setting for Substation (excel sheet + explanation)
🔸https://elec-engg.com/relay-coordination-and-setting-for-substation-excel-sheet-explanation/
@Elec_Engg
#Protection #Course
🔷SIEMENS Electrical Protection Course Materials (Basic)
🔸https://elec-engg.com/siemens-electrical-protection-course-materials-basic/
🔷SIEMENS Electrical Protection Course Materials (Basic)
🔸https://elec-engg.com/siemens-electrical-protection-course-materials-basic/
#Protection #Course
🔷SIEMENS Electrical Protection Course Materials (Advance)
🔸https://elec-engg.com/siemens-electrical-protection-course-materials-advance/
https://t.me/joinchat/AAAAAE69dV8G1UIbXiSqRA
🔷SIEMENS Electrical Protection Course Materials (Advance)
🔸https://elec-engg.com/siemens-electrical-protection-course-materials-advance/
https://t.me/joinchat/AAAAAE69dV8G1UIbXiSqRA
#MV #LV #Test_Procedure
🔷Medium Voltage and Low Voltage Switchgear Test Procedure
https://elec-engg.com/medium-voltage-and-low-voltage-switchgear-test-procedure/
@Elec_Engg
🔷Medium Voltage and Low Voltage Switchgear Test Procedure
https://elec-engg.com/medium-voltage-and-low-voltage-switchgear-test-procedure/
@Elec_Engg
#SIEMENS #DIGSI #DIGSI4
🔷Digsi 4 installation Guide with Serial Number
https://elec-engg.com/digsi-serial-number/
🔷Digsi 4 installation Guide with Serial Number
https://elec-engg.com/digsi-serial-number/
#SIEMENS #DIGSI #SIGRA
🔷Process data analysis with SIGRA
https://elec-engg.com/process-data-analysis-with-sigra-4/
@Elec_Engg
🔷Process data analysis with SIGRA
https://elec-engg.com/process-data-analysis-with-sigra-4/
@Elec_Engg
#SIEMENS #SIPROTEC #Distance #Course
🔷Advance Distance Protection (Based on the SIPROTEC Relays)
https://elec-engg.com/advance-distance-protection-based-on-the-siprotec-relays/
@Elec_Engg
🔷Advance Distance Protection (Based on the SIPROTEC Relays)
https://elec-engg.com/advance-distance-protection-based-on-the-siprotec-relays/
@Elec_Engg
#SIEMENS #REYROLLE #Catalogue
🔷SPDL – Reyrolle Product Introduction
🔶https://elec-engg.com/spdl-reyrolle/
@Elec_Engg
🔷SPDL – Reyrolle Product Introduction
🔶https://elec-engg.com/spdl-reyrolle/
@Elec_Engg
#SIPROTEC #Diagram #Protection
🔷GeneratorTransformer Protection System full diagram based on SIPROTEC Siemens Relays
🔶https://elec-engg.com/generatortransformer-protection-system-full-diagram-based-on-siprotec-siemens-relays/
🔷GeneratorTransformer Protection System full diagram based on SIPROTEC Siemens Relays
🔶https://elec-engg.com/generatortransformer-protection-system-full-diagram-based-on-siprotec-siemens-relays/
#Course #Protection #Substation
🔷Protection, synchronization, and measurement system in the generation station
🔶https://elec-engg.com/protection-course/
@Elec_Engg
🔷Protection, synchronization, and measurement system in the generation station
🔶https://elec-engg.com/protection-course/
@Elec_Engg